• JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker
  • JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker
  • JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker
  • JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker
  • JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker
  • JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker
  • JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker
  • JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker

JCB2LE-80M4P 4 Pole RCBO 6kA Residual Current Circuit Breaker

The JCB2LE-80M RCBOs (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.
Electronic Type
Residual current protection
Overload and short circuit protection
Breaking capacity 6kA
Rated current up to 80A (available from 6A to 80A)
Available in B Curve or C tripping curves.
Tripping sensitivity: 30mA,100mA,300mA
Type A or Type AC are available
Double pole switching for complete isolation of faulty circuits
Neutral pole switching significantly reduces the installation and commissioning test time
Complies with IEC 61009-1, EN61009-1

Introduction:

JCB2LE-80M4P RCBO combines RCD and MCB protection in a 4 module wide device and is operating for unbalanced loads and balanced loads, 3 phase protection in DIN rail distribution box.

JCB2LE-80M4P RCBO (Residual Current Circuit Breaker with Overload Protection) provides residual and overload protection in one neat device. The breaking capacity is up to 6kA. The rate current is up to 80Amps. It is available in 6A, 10A, 16A, 20A, 32A, 40A, 50A, 63A,80A. It is available in A type and AC type. Type AC RCBOs are used for general purpose on AC (Alternating Current) only circuits. Type A are used for DC (Direct Current) protection. Available in 30mA,100mA,300mA tripping sensitivity. Available in B, C ,D tripping curves.

JCB2LE-80M4P RCBO is commonly used in applications where there is the need to combine protection against overcurrents (overload and short-circuit) and protection against earth leakage currents. They help in sensing this kind of faults and trip the circuit ensuring complete protection of the people and connected equipment

JCB2LE-80M4P RCBO is purposed to protect one from the risk of electrical shocks, firesand electrocution. It can also assist in sudden earth faults. The installation of an JCB2LE-80M4P RCBO ensures that a circuit trips immediately and protects you from electric shock.

JCB2L3-80M4P comply with IEC 61009-1, EN61009-1 standard.

Product Description:

JCB2LE-80M 4P

Main Features

● Electronic Type 4 pole

● Earth leakage protection

● Overload and short circuit protection

● Non Line / Load sensitive

● Breaking capacity up to 6kA

● Rated current up to 80A (available in 6A.10A,20A, 25A, 32A, 40A,50A, 63A, 80A)

● Available in B type, C type tripping curves.

● Tripping sensitivity: 30mA,100mA, 300mA

● Type A or Type AC are available

● Insulated openings for easy busbar installations

● 35mm DIN rail mounting

● Compatible with multiple types of screw-drivers with combination head screws

● Meets ESV Additional Testing & verification requirements for RCBOs

● Complies with IEC 61009-1, EN61009-1

 

Technical Data

● Standard: IEC 61009-1, EN61009-1

● Type: Electronic

● Type (wave form of the earth leakage sensed): A or AC are available

● Poles: 4 pole

● Rated current:6A, 10A, 16A, 20A, 25A, 32A, 40A 50A, 63A, 80A

● Rated working voltage: 400V, 415V ac

● Rated sensitivity I△n: 30mA, 100mA, 300mA

● Rated breaking capacity: 6kA

● Insulation voltage: 500V

● Rated frequency: 50/60Hz

● Rated impulse withstand voltage(1.2/50) : 6kV

● Pollution degree:2

● Thermo- magnetic release characteristic: B curve, C curve, D curve

● Mechanical life: 10,000 times

● Electrical life: 2000 times

● Protection degree: IP20

● Ambient temperature (with daily average ≤35℃):-5℃~+40℃

● Contact position indicator: Green=OFF, Red=ON

● Terminal connection type:Cable/U-type busbar/Pin-type busbar

● Mounting: On DIN rail EN 60715 ( 35mm) by means of fast clip device

● Recommended torque: 2.5N.m

● Connection: From top or bottom are available

Standard

IEC61009-1 ,  EN61009-1

Electrical

features

Rated current In (A)

6, 10, 16, 20, 25, 32, 40,50,63,80

Type

Eletronic

Type (wave form of the earth leakage sensed)

A or AC are available

Poles

4 Pole

Rated voltage Ue(V)

230/240

Rated sensitivity I△n

30mA,100mA,300mA

Insulation voltage Ui (V)

500

Rated frequency

50/60Hz

Rated breaking capacity

6kA

Rated impulse withstand voltage(1.2/50) Uimp (V)

6000

Pollution degree

2

Thermo-magnetic release characteristic

B, C

Mechanical

features

Electrical life

2, 000

Mechanical life

10, 000

Contact position indicator

Yes

Protection degree

IP20

Reference temperature for setting of thermal element(℃)

30

Ambient temperature (with daily average ≤35℃)

-5...+40

Storage temperation (℃)

-25...+70

Installation

Terminal connection type

Cable/U-type busbar/Pin-type busbar

Terminal size top/bottom for cable

25mm2  / 18-4 AWG

Terminal size top/bottom for Busbar

10mm2  / 18-8 AWG

Tightening torque

2.5 N*m  /  22 In-Ibs.

Mounting

On DIN rail EN 60715 (35mm) by means of fast clip device

Connection

From top

JCB2LE-80M 4P 2

JCB2LE-80M4P Dimensions

JCB2LE-80M 4P Dimension

Respect for the environment – Compliance with European Union Directives:

Compliance with Directive 2002/95/EC of 27/01/03 known as "RoHS" which provides for a restriction on the use of dangerous substances such as lead, mercury, cadmium, hexavalent chromium and polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) brominated flame retardants from 1st July 2006. Compliance with the Directive 91/338/EEC of 18/06/91 and decree 94-647 of 27/07/0.

Message us