• JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker
  • JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker

JCB2LE-80M 2 Kutub RCBO Residual Current Breaker Kalawan Leuwih Arus jeung Leakage panyalindungan, Diferensial circuit breaker

The JCB2LE-80M RCBOs (residual circuit breaker kalawan panyalindungan overload) cocog pikeun unit konsumen atawa papan distribusi, dilarapkeun dina kaayaan sapertos industri, sarta komérsial, wangunan luhur-naékna jeung imah padumukan.

Diferensial circuit breaker
Tipe éléktronik
Perlindungan arus sésa
Overload sareng panyalindungan sirkuit pondok
Megatkeun kapasitas 6kA, éta bisa ditingkatkeun jadi 10kA
Dipeunteun ayeuna nepi ka 80A (sadia ti 6A ka 80A)
Sadia dina kurva B atanapi C tripping kurva.
Sensitipitas tripping: 30mA, 100mA, 300mA
Tipe A atanapi Tipe AC sayogi
Ganda kutub switching pikeun isolasi lengkep sirkuit faulty
Ngalihkeun kutub nétral sacara signifikan ngirangan pamasangan sareng waktos uji komisioning
Sasuai jeung IEC 61009-1, EN61009-1

bubuka:

JCB2LE-80M RCBO (residual circuit breaker kalawan panyalindungan overload) nyadiakeun panyalindungan ngalawan faults bumi, overloads, sirkuit pondok.Éta cocog pikeun unit konsumen atanapi papan distribusi, diterapkeun dina kaayaan sapertos industri, sareng komérsial, gedong luhur sareng bumi padumukan.
JCB2LE-80M RCBO leuwih aman jeung duanana dipegatkeun nétral jeung fase jaminan actuation ditangtoskeun na ngalawan leakage faults bumi sanajan nétral jeung fase nu wrongly disambungkeun.
JCB2LE-80M mangrupakeun tipe éléktronik RCBO, nu incorporates alat nyaring nyegah resiko nu teu dihoyongkeun alatan tegangan fana jeung arus Transient.
JCB2LE-80M RCBOs fitur dual kutub switching kalawan disconnection hirup jeung nétral.Sadia salaku Tipe AC (pikeun arus bolak wungkul) atawa Tipe A (pikeun arus bolak-balik jeung pulsating DC)
JCB2LE-80M RCBO dina 2 kutub jeung 1P + N mangrupakeun kualitas luhur residual circuit breaker jeung miniatur circuit breaker kombinasi jeung garis tegangan-gumantung tripping jeung rupa-rupa dipeunteun tripping arus.Éléktronik anu diwangun sacara saksama ngawaskeun aliran arus.Beda antara arus residual anu teu bahaya sareng kritis bakal dideteksi.
JCB2LE-80M ROBO nyaéta sadia dina 6A, 10A, 16A, 20A, 32A, 40A, 50A, 63A, 80A.Pilihan ageung tina rating ayeuna pikeun sadaya aplikasi komérsial sareng industri.Sensitipitas tripping sayogi dina 30mA, 100mA, 300mA.Éta sayogi dina kurva tripping Tipe B atanapi C.Éta ogé sayogi dina versi tegangan rendah anu dirancang pikeun dianggo dina sistem 110V.Tombol test inbuilt beroperasi dina tegangan dipeunteun
JCB2LE-80M RCBO nyadiakeun panyalindungan teu langsung ka awak operator dina kaayaan sapertos nu bagian hirup kakeunaan kudu disambungkeun ka kutub bumi ditangtoskeun.Ogé nyadiakeun panyalindungan overcurrent kana sirkuit di rumah tangga, komérsial, sarta pamasangan sarupa lianna.Leuwih ti éta, éta nyegah potensi bahaya seuneu disababkeun ku lepat bumi ayeuna bisi alat panyalindungan overcurrent gagal.
JCB2LE-80M RCBO ngabogaan rating 6kA idéal pikeun aplikasi komérsial sarta padumukan.Kombo RCD / MCB bakal ngajagi harta sareng kahirupan kedah ayeuna dideteksi bocor ka bumi dina 30mA.Switch ngabogaan switch test inbuilt sarta gampang ngareset sanggeus sesar ieu rectified.

Panjelasan Produk:

JCB2LE-80M

Fitur Utama

● Tipe éléktronik

● panyalindungan leakage bumi

● Overload jeung perlindungan circuit pondok

● Non Line / Beban sénsitip

● Kapasitas megatkeun nepi ka 6kA, bisa ditingkatkeun nepi ka 10kA

● Dipeunteun ayeuna nepi ka 80A (sadia dina 6A.10A, 20A, 25A, 32A, 40A, 50A, 63A, 80A)

● Sadia dina tipe B, C tipe tripping kurva.

● Tripping sensitipitas: 30mA, 100mA, 300mA

● Tipe A atawa Tipe AC sadia

● Leres Double Kutub Disconnection dina RCBO Module ganda

● Disconnects LIVE & nétral konduktor on duanana kaayaan Sesar Ayeuna na overload

● nétral kutub switching nyata ngurangan instalasi tur commissioning waktos test

● Insulated bukaan pikeun instalasi busbar gampang

● 35mm DIN rail ningkatna

● kalenturan Instalasi jeung pilihan sambungan garis boh ti luhur atawa handap

● Cocog jeung sababaraha jenis screw-drivers kalawan screws sirah kombinasi

● Meets ESV Testing Tambahan & syarat verifikasi pikeun RCBOs

● Sasuai jeung IEC 61009-1, EN61009-1

 

Data Téknis

● Baku: IEC 61009-1, EN61009-1

● Tipe: éléktronik

● Tipe (bentuk gelombang tina leakage bumi sensed): A atawa AC sadia

● Kutub: 2 kutub, 1P + N

● dipeunteun ayeuna: 6A, 10A, 16A, 20A, 25A, 32A, 40A 50A, 63A, 80A

● tegangan kerja dipeunteun: 110V, 230V, 240V ~ (1P + N)

● Dipeunteun sensitipitas I△n: 30mA, 100mA, 300mA

● dipeunteun kapasitas megatkeun: 6kA

● tegangan insulasi: 500V

● frékuénsi dipeunteun: 50/60Hz

● dorongan dipeunteun tahan tegangan (1.2/50): 6kV

● Gelar polusi:2

● Thermo- karakteristik release magnét: kurva B, kurva C, kurva D

● Kahirupan mékanis: 10.000 kali

● hirup listrik: 2000 kali

● gelar Protection: IP20

● hawa ambient (kalawan rata poean ≤35 ℃): -5 ℃ ~ + 40 ℃

● Indikator posisi kontak: Héjo = OFF, Beureum = ON

● Tipe sambungan Terminal: Kabel / U-tipe busbar / Pin-tipe busbar

● dipasang: Dina DIN rail EN 60715 ( 35mm) ku cara maké alat klip gancang

● torsi dianjurkeun: 2.5Nm

● Sambungan: Ti luhur atawa handap sadia

Standar

IEC61009-1, EN61009-1

Listrik

Fitur

Dipeunteun ayeuna Dina (A)

6, 10, 16, 20, 25, 32, 40,50,63,80

Tipe

Éléktronik

Jenis (bentuk gelombang tina bocor bumi dirasakeun)

A atanapi AC sayogi

Kutub

2 Kutub

Tegangan dipeunteun Ue (V)

230/240

Sensitipitas dipeunteun I△n

30mA, 100mA, 300mA sayogi

Tegangan insulasi Ui (V)

500

Frékuénsi dipeunteun

50/60Hz

Kapasitas pegatna dipeunteun

6kA

Dipeunteun impuls tahan tegangan (1.2/50) Uimp (V)

6000

Gelar polusi

2

Ciri pelepasan termo-magnétik

B, C

Mékanis

Fitur

Kahirupan listrik

2.000

Kahirupan mékanis

10.000

Indikator posisi kontak

Sumuhun

Gelar panyalindungan

IP20

Suhu rujukan pikeun netepkeun unsur termal (℃)

30

Suhu ambient (kalayan rata-rata poean ≤35 ℃)

-5...+40

Suhu neundeun (℃)

-25...+70

Pamasangan

Jenis sambungan terminal

kabel / U-tipe busbar / Pin-tipe busbar

Ukuran terminal luhur / handap pikeun kabel

25 mm2/ 18-3 AWG

Ukuran terminal luhur / handap pikeun Busbar

10 mm2 / 18-8 AWG

Torsi tightening

2,5 N*m / 22 Dina-Ibs.

Pamasangan

Dina rel DIN EN 60715 (35mm) ku alat klip gancang

Sambungan

Ti luhur atawa handap sadia

JCB2LE-80M 2

Diménsi

JCB2LE-80M Diménsi

Naon ari RCBO sareng Kumaha Gawéna?
RCBO nangtung pikeun 'Residual Current Breaker with Over-Current'.Sakumaha ngaranna nunjukkeun eta ngajaga ngalawan dua jenis sesar sarta dina dasarna ngagabungkeun pungsionalitas hiji MCB na RCD.

 

Hayu urang mimiti ngingetkeun diri urang dua kasalahan:
1.Arus résidual, atawa Leakage Bumi - lumangsung nalika aya putus teu kahaja dina sirkuit ngaliwatan wiring listrik goréng atawa kacilakaan DIY kayaning pangeboran ngaliwatan kabel nalika ningkatna hook gambar atawa motong ngaliwatan kabel jeung mower padang rumput hejo.Dina hal ieu, listrik kedah angkat ka mana waé sareng milih jalur anu paling gampang ngalangkungan mesin pemotong rumput atanapi bor ka manusa anu nyababkeun shock listrik.
2. Over-Current nyandak dua bentuk:
2.1 Overload - Kajadian nalika seueur teuing alat anu dianggo dina sirkuit, ngagambar jumlah kakuatan anu ngaleuwihan kapasitas kabel.
2.2 Sirkuit pondok - Kajadian nalika aya hubungan langsung antara konduktor hirup sareng nétral.Tanpa résistansi anu disayogikeun ku integritas sirkuit normal, arus listrik nyéépkeun sirkuit dina loop sareng ngalikeun amperage ku sababaraha rébu kali dina ngan milliseconds sareng langkung bahaya tibatan Overload.
Sedengkeun RCD dirancang ngan ukur pikeun ngalindungan tina bocor bumi sareng MCB ngan ukur ngajagi tina arus langkung, RCBO ngajagi tina dua jinis sesar.

Pesen kami