• JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial
  • JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial

JCB2LE-80M 2 Pole RCBO Pemutus Sirkuit Arus Sisa Kanthi proteksi Arus lan Kebocoran, Pemutus Sirkuit Diferensial

RCBO JCB2LE-80M (pemutus sirkuit arus sisa kanthi proteksi kakehan) cocok kanggo unit konsumen utawa papan distribusi, ditrapake ing acara kayata industri, lan komersial, bangunan dhuwur lan omah omah.

Pemutus sirkuit diferensial
Tipe Elektronika
Proteksi arus sisa
Kakehan lan pangayoman short circuit
Breaking kapasitas 6kA, iku bisa nganyari kanggo 10kA
Dirating saiki nganti 80A (kasedhiya saka 6A nganti 80A)
Kasedhiya ing kurva B utawa C tripping kurva.
Sensitivitas tripping: 30mA, 100mA, 300mA
Tipe A utawa Tipe AC kasedhiya
Ngalih kutub dobel kanggo isolasi lengkap sirkuit sing rusak
Ngalih kutub Neutral nyuda wektu tes instalasi lan komisioning
Selaras karo IEC 61009-1, EN61009-1

Pambuka:

JCB2LE-80M RCBO (sisan mbobol sirkuit saiki karo pangayoman kakehan) menehi pangayoman marang bentet bumi, overloads, short circuits.Padha cocok kanggo unit konsumen utawa Papan distribusi, Applied ing kesempatan kayata industri, lan komersial, bangunan dhuwur lan omah omah.
JCB2LE-80M RCBO luwih aman karo loro netral pedhot lan phase njamin aktuasi sing tepat marang bentet bocor bumi sanajan Neutral lan phase disambungake salah.
JCB2LE-80M minangka RCBO jinis elektronik, sing nggabungake piranti nyaring nyegah risiko sing ora dikarepake amarga voltase transien lan arus Transient.
JCB2LE-80M RCBOs fitur dual pole ngoper karo pedhot urip lan netral.Kasedhiya minangka Tipe AC (mung kanggo arus bolak-balik) utawa Tipe A (kanggo arus DC bolak-balik lan pulsating)
JCB2LE-80M RCBO ing 2 kutub lan 1P + N punika kualitas dhuwur ampas sirkuit mbobol lan miniatur sirkuit mbobol kombinasi karo line voltase-gumantung tripping lan macem-macem dirating saiki tripping.Elektronik sing dibangun kanthi tepat ngawasi aliran arus.Bentenipun antarane arus residual sing ora mbebayani lan kritis bakal dideteksi.
JCB2LE-80M ROBO kasedhiya ing 6A, 10A, 16A, 20A, 32A, 40A, 50A, 63A, 80A.Pilihan akeh rating saiki kanggo kabeh aplikasi komersial lan industri.Sensitivitas tripping kasedhiya ing 30mA, 100mA, 300mA.Kasedhiya ing kurva tripping Tipe B utawa C.Uga kasedhiya ing versi voltase kurang sing dirancang kanggo digunakake ing sistem 110V.Tombol test inbuilt makaryakke ing voltase dirating
JCB2LE-80M RCBO menehi pangayoman ora langsung kanggo awak operator ing kahanan kuwi sing bagean urip kapapar kudu disambungake menyang kutub bumi sing tepat.Iki uga nyedhiyakake proteksi arus kakehan kanggo sirkuit ing rumah tangga, komersial, lan instalasi sing padha.Kajaba iku, nyegah bebaya geni sing disebabake dening arus bumi yen piranti proteksi overcurrent gagal.
JCB2LE-80M RCBO nduweni rating 6kA sing cocog kanggo aplikasi komersial lan omah.Kombo RCD / MCB bakal nglindhungi properti lan urip kudu dideteksi bocor ing bumi sajrone 30mA.Ngalih duwe switch test inbuilt lan gampang direset sawise fault wis rectified.

Deskripsi Produk:

JCB2LE-80M

Fitur Utama

● Jinis Elektronik

● Proteksi bocor bumi

● Overload lan short circuit pangayoman

● Non Line / Load sensitif

● Kapasitas breaking nganti 6kA, bisa upgrade kanggo 10kA

● Dirating saiki nganti 80A (kasedhiya ing 6A.10A, 20A, 25A, 32A, 40A, 50A, 63A, 80A)

● Kasedhiya ing jinis B, C jinis tripping kurva.

● Sensitivitas tripping: 30mA, 100mA, 300mA

● Tipe A utawa Tipe AC kasedhiya

● True Double Pole Disconnection ing RCBO Modul pindho

● Medhot konduktor LIVE & Neutral ing loro kondisi Fault Saiki lan kakehan

● Neutral pole ngoper Ngartekno nyuda instalasi lan commissioning wektu test

● Bukaan terisolasi kanggo instalasi busbar gampang

● 35mm DIN alur soyo tambah

● keluwesan Instalasi karo pilihan saka sambungan line salah siji saka ndhuwur utawa ngisor

● Kompatibel karo macem-macem jinis screw-driver karo kombinasi sirah ngawut-awut

● Meet ESV Testing Tambahan & syarat verifikasi kanggo RCBOs

● Selaras karo IEC 61009-1, EN61009-1

 

Data Teknis

● Standar: IEC 61009-1, EN61009-1

● Jinis: Elektronik

● Tipe (bentuk gelombang saka bocor bumi sensed): A utawa AC kasedhiya

● Kutub: 2 kutub, 1P+N

● Rated saiki: 6A, 10A, 16A, 20A, 25A, 32A, 40A 50A, 63A, 80A

● Rated tegangan kerja: 110V, 230V, 240V ~ (1P + N)

● Dirating sensitivitas I△n: 30mA, 100mA, 300mA

● Dirating kapasitas bejat: 6kA

● Tegangan isolasi: 500V

● Dirating frekuensi: 50/60Hz

● Rated impuls tahan voltase (1.2/50): 6kV

● Tingkat polusi:2

● Karakteristik pelepasan termomagnetik: kurva B, kurva C, kurva D

● urip mekanik: 10.000 kaping

● urip listrik: 2000 kaping

● Gelar pangayoman: IP20

● Suhu sekitar (kanthi rata-rata saben dina ≤35 ℃): -5 ℃ ~ + 40 ℃

● Indikator posisi kontak: Green=OFF, Red=ON

● Jinis sambungan terminal: Kabel / U-jinis busbar / Pin-jinis busbar

● Pemasangan: Ing rel DIN EN 60715 ( 35mm) kanthi piranti klip cepet

● Rekomendasi torsi: 2.5Nm

● Sambungan: Saka ndhuwur utawa ngisor kasedhiya

Standar

IEC61009-1, EN61009-1

listrik

fitur

Rated saiki In (A)

6, 10, 16, 20, 25, 32, 40,50,63,80

Jinis

elektronik

Tipe (bentuk gelombang saka bocor bumi sing dirasakake)

A utawa AC kasedhiya

Kutub

2 Kutub

Tegangan Rated Ue(V)

230/240

Sensitivitas dirating I△n

30mA, 100mA, 300mA kasedhiya

Tegangan isolasi Ui (V)

500

frekuensi dirating

50/60Hz

Kapasitas rusak sing dirating

6kA

Tegangan tahan impuls sing dirating (1.2/50) Uimp (V)

6000

Gelar polusi

2

Karakteristik release termo-magnetik

B, C

Mekanik

fitur

urip listrik

2.000

urip mekanik

10.000

Indikator posisi kontak

ya wis

Gelar pangayoman

IP20

Suhu referensi kanggo nyetel unsur termal (℃)

30

Suhu sekitar (kanthi rata-rata saben dina ≤35 ℃)

-5...+40

Suhu panyimpenan (℃)

-25...+70

Instalasi

Tipe sambungan terminal

Kabel/U-jinis busbar/pin-jinis busbar

Ukuran terminal ndhuwur / ngisor kanggo kabel

25 mm2/ 18-3 AWG

Ukuran terminal ndhuwur / ngisor kanggo Busbar

10 mm2 / 18-8 AWG

Torsi tightening

2,5 N*m / 22 Ing-Ibs.

Pemasangan

Ing rel DIN EN 60715 (35mm) kanthi piranti klip cepet

Sambungan

Saka ndhuwur utawa ngisor kasedhiya

JCB2LE-80M 2

ukuran

Ukuran JCB2LE-80M

Apa RCBO lan Cara Kerjane?
RCBO singkatan saka 'Residual Current Breaker with Over-Current'.Minangka jeneng tabet nglindhungi marang rong jinis fault lan ing inti nggabungke fungsi saka MCB lan RCD.

 

Ayo kita ngelingake awake dhewe babagan loro kesalahan kasebut:
1.Arus Sisa, utawa Kebocoran Bumi - Kedadeyan nalika ana break sengaja ing sirkuit liwat kabel listrik miskin utawa kacilakan DIY kayata pengeboran liwat kabel nalika soyo tambah pancing gambar utawa nglereni liwat kabel karo mower pekarangan.Ing kasus iki, listrik kudu pindhah menyang endi wae lan milih rute sing paling gampang liwat mesin pemotong rumput utawa pengeboran menyang manungsa sing nyebabake kejut listrik.
2. Over-Current njupuk rong wujud:
2.1 Kakehan - Kedadeyan nalika akeh banget piranti digunakake ing sirkuit, tarik jumlah daya kang ngluwihi kapasitas kabel.
2.2 Short Circuit - Kedadeyan nalika ana sambungan langsung antarane konduktor urip lan netral.Tanpa resistensi sing diwenehake dening integritas sirkuit normal, arus listrik ngubengi sirkuit ing daur ulang lan nambah amperage kaping pirang-pirang ing mung milliseconds lan luwih mbebayani tinimbang Overload.
Dene RCD dirancang mung kanggo nglindhungi saka bocor bumi lan MCB mung nglindhungi saka over-saiki, RCBO nglindhungi saka loro jinis fault.