• JC3LE-4P  4 Pole Electromagnetic RCBO
  • JC3LE-4P  4 Pole Electromagnetic RCBO
  • JC3LE-4P  4 Pole Electromagnetic RCBO
  • JC3LE-4P  4 Pole Electromagnetic RCBO
  • JC3LE-4P  4 Pole Electromagnetic RCBO
  • JC3LE-4P  4 Pole Electromagnetic RCBO

JC3LE-4P 4 Pole Electromagnetic RCBO

Electromagnetic Type
Residual current (rcd) protection
Earth Leakage protection
Overload and short circuit protection
Breaking capacity 10KA
Rated current up to 63A(available from 6A to 63A)
Available in B or C tripping curves
Type A or Type AC are avaible
Tripping sensitivity: 30mA,100mA,300mA
Connection from top or bottom are available
Neutral pole switching significantly reduces the installation and commissioning test time
Double handle (one control MCB, another control RCD)
Complies with IEC61009-1, EN61009-1

Features
Electromagnetic Type
Residual current (rcd) protection
Earth Leakage protection
Overload and short circuit protection
Breaking capacity 10KA
Rated current up to 63A(available from 6A to 63A)
Available in B or C tripping curves
Type A or Type AC are avaible
Tripping sensitivity: 30mA,100mA,300mA
Connection from top or bottom are available
Neutral pole switching significantly reduces the installation and commissioning test time
Double handle (one control MCB, another control RCD)
Complies with IEC61009-1, EN61009-1

Non Neutral Specific
JC3LE-4P is a true 4 pole RCBO that offers unparalleled safety features for residential, commercial and industrial applications. Every pole can provide overload and short circuit protection. It can significantly reduce the risk of electric shock and equipment damage, safer and more reliable. You can choose any one pole as the Neutral according to your actual needs.

Application
The JC3LE-4P RCBO (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses

Technical Data

  Standard IEC61009-1, EN61009-1
Electrical features Rated current In (A) 6, 10, 16, 20, 25, 32, 40
Type Electromagnetic
Type(wave from of the earth leakage sensed) A are available
Poles 4 Pole
Rated voltage Ue (V) 400/415
Rated sensitivity IΔn 30mA, 100mA, 300mA
Insulation voltage Ui (V) 500
Rated frequency 50/60Hz
Rated breaking capacity 6KA
Rated impulse withstand voltage (1.2/50) Uimp (V) 6,000
Dielectric test voltage at ind.Freq. for 1 min (KV) 2
Pollution degree 2
Thermo-magnetic release characteristic B, C
Mechanical features Electrical life 2,000
Mechanical life 10,000
Contact position indicator Yes
Protection degree IP20
Reference temperature for setting of thermal element() 30
Ambient temperature(with daily average 35) -5+40
Storage temperature() -25+70
Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for cable 25mm2/18-3AWG
Terminal size top/bottom for Busbar 10mm2/18-8AWG
Tightening torque 2.5N*m/22In-lbs
Mounting On DIN rail EN 60715(35mm)
Connection From top or bottom are available

Message us