JC3LE-EV Type EV 2 Pole RCBO 10KA
Electromagnetic Type
Residual current (rcd) protection
Earth Leakage protection
Overload and short circuit protection
Breaking capacity 10KA
Rated current up to 63A(available from 6A to 63A)
Available in B or C tripping curves
Type A or Type AC are avaible
Tripping sensitivity: 30mA,100mA,300mA
Connection from top or bottom are available
Neutral pole switching significantly reduces the installation and commissioning test time
Double handle (one control MCB, another control RCD)
Complies with IEC61009-1, EN61009-1
Features
Electromagnetic Type
Residual current (rcd) protection
Earth Leakage protection
Overload and short circuit protection
Breaking capacity 10KA
Rated current up to 63A(available from 6A to 63A)
Available in B or C tripping curves
Type A or Type AC are avaible
Tripping sensitivity: 30mA,100mA,300mA
Connection from top or bottom are available
Neutral pole switching significantly reduces the installation and commissioning test time
Double handle (one control MCB, another control RCD)
Complies with IEC61009-1, EN61009-1
Application
The JC3LE-EV RCBO (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses
Technical Data
| Product code | JC3LE-EV | |
| Standard | IEC61009-1, EN61009-1 | |
| Electrical features | Rated current In (A) | 6, 10, 16, 20, 25, 32, 40, 63 |
| Type | Electronic | |
| Type(wave from of the earth leakage sensed) | A are available | |
| Poles | 2Pole | |
| Rated voltage Ue (V) | 230/240 | |
| Rated sensitivity IΔn | 30mA, 100mA, 300mA | |
| Insulation voltage Ui (V) | 500 | |
| Rated frequency | 50/60Hz | |
| Rated breaking capacity | 6KA | |
| Rated impulse withstand voltage (1.2/50) Uimp (V) | 6,000 | |
| Dielectric test voltage at ind.Freq. for 1 min (KV) | 2 | |
| Pollution degree | 2 | |
| Thermo-magnetic release characteristic | B, C | |
| Mechanical features | Electrical life | 2,000 |
| Mechanical life | 10,000 | |
| Contact position indicator | Yes | |
| Protection degree | IP20 | |
| Reference temperature for setting of thermal element(℃) | 30 | |
| Ambient temperature(with daily average ≤35℃) | -5…+40 | |
| Storage temperature(℃) | -25…+70 | |
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar |
| Terminal size top/bottom for cable | 25mm2/18-3AWG | |
| Terminal size top/bottom for Busbar | 10mm2/18-8AWG | |
| Tightening torque | 2.5N*m/22In-lbs | |
| Mounting | On DIN rail EN 60715(35mm) | |
| Connection | From top or bottom are available | |