JC3BE Miniature Circuit Breaker (MCB) 15KA

Protection of circuits against short-circuit currents;

Protection of circuits against overload currents;

Breaking capacity up to 15kA

With contact indicator

Can be made from 1A to 80A

1 Pole, 2 Pole, 3 Pole , 4 Pole are available

B , C or D curve

Comply with IEC 60947-2

Features

Protection of circuits against short-circuit currents;

Protection of circuits against overload currents;

Breaking capacity up to 15kA

With contact indicator

Can be made from 1A to 80A

1 Pole, 2 Pole, 3 Pole , 4 Pole are available

B , C or D curve

Comply with IEC 60947-2

Application

JC3BE circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.

Selection

Technical data of the network at the point considered: the earthing systems (TNS, TNC),short-circuit current at the circuit-breaker installation point,which must always be less than the breaking capacity of this device, network normal voltage.

Tripping curves:

B curve (3-5ln)---protection for people and big length cables in TN and IT systems.

C curve (5-10ln)---protection for resistive and inductive loads with low inrush current

D curve(10-14ln)---protection for circuits which supply loads with high inrush current at the circuit.closing (LV/LV transformers, breakdown lamps)(Defaulted) D curve could be also made in 10-20ln

Technical Data

Product code JC3BE
  Standard IEC60898-1 IEC60947-2
Electrical features Rated current In(A) 1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80
Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P
Rated voltage Ue(A) 230/400~   240/415~
Insulation voltage Ui(A) 500
Rated frequency 50/60Hz
Rated breaking capacity 15KA
Energy limiting class 3
Rated impulse withstand voltage(1.2/50)Uimp(A) 4000
Dielectric test voltage at ind.Fred.for 1 min (KV) 2
Pollution degree 2
Power loss per pole 1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80
Thermo-magnetic release characteristic B, C, D 8-12In, 9.6-14.4In
Mechanical features Electrical life 4000
Mechanical life 20000
Contact position indicator Yes
Protection degree IP 20
Reference temperature for setting of thermal element() 30
Ambient temperature(with daily average35) -5+40
Storage temperature -25+70
Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for cable 25mm2/18-4AWG
Terminal size top/bottom for busbar 10mm2/18-8AWG
Tightening torque 2.5N*m/22In-Ibs.
Mounting On Din rail EN 60715(35mm)
Connection Form top and bottom
Combination with accessories Auxiliary contact Yes
Shunt release Yes
Under voltage release Yes
Alarm contact Yes