• JCB2LE-EV RCBO Type EV 1P+N
  • JCB2LE-EV RCBO Type EV 1P+N
  • JCB2LE-EV RCBO Type EV 1P+N
  • JCB2LE-EV RCBO Type EV 1P+N
  • JCB2LE-EV RCBO Type EV 1P+N
  • JCB2LE-EV RCBO Type EV 1P+N

JCB2LE-EV RCBO Type EV 1P+N

Electronic Type
Earth leakage protection
Overload and short circuit protection
Breaking capacity 6 kA (6 A to 40A ca n be up graded to 10 kA) Rated current up to 40A (available from 6A to 40A) Type Evareavaiable
Tripping sensitivity: 30mA, 100mA
Double pole switching for complete isolation of faulty circuits Neutral pole switching significantly reduces the installation and commissioning test time
Complies with IEC61009-1.EN61009-1
Internally equipped with physical break points

Features

Electronic Type
Earth leakage protection
Overload and short circuit protection
Breaking ca pa city 6 ka (6 A to 40A ca n be up graded to 10 kA) Rated current up to 40A (available from 6A to 40A) Type Evareavaiable
Tripping sensitivity : 30mA,100mA
Double pole switching for complete isolation of faulty circuits Neutral pole switching significantly reduces the installation and commissioning test time
Complies with IEC61009-1.EN61009-1
Internally equipped with physical break points

Application
The JCB2LE- EV RCBOs (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high- rise buildings and residential houses

Switched Live and Neutral
JCB2LE- EV rcbo with swltched neutal built in as standard will fully isolate a faulty or damaged circuit by disconnecting live and neutral conductors. They offers the most comprehens circuit protection avaiable

Technical Data

Product code JCB2LE-EV
Standard IEC61009-1, EN61009-1
Electrical features Rated current In (A) 6, 10, 16, 20, 25, 32, 40, 63
Type Electronic
Type(wave from of the earth leakage sensed) A are available
Poles 2Pole
Rated voltage Ue (V) 230/240
Rated sensitivity IΔn 30mA, 100mA, 300mA
Insulation voltage Ui (V) 500
Rated frequency 50/60Hz
Rated breaking capacity 6KA
Rated impulse withstand voltage (1.2/50) Uimp (V) 6,000
Dielectric test voltage at ind.Freq. for 1 min (KV) 2
Pollution degree 2
Thermo-magnetic release characteristic B, C
Mechanical features Electrical life 2,000
Mechanical life 10,000
Contact position indicator Yes
Protection degree IP20
Reference temperature for setting of thermal element() 30
Ambient temperature(with daily average 35) -5+40
Storage temperature() -25+70
Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for cable 25mm2/18-3AWG
Terminal size top/bottom for Busbar 10mm2/18-8AWG
Tightening torque 2.5N*m/22In-lbs
Mounting On DIN rail EN 60715(35mm)
Connection From top or bottom are available