JC3RS-B Residual Current Device

Electromagnetic Type
Earth Leakage Protection
Breaking capacity 6KA,10KA
Rated current up to 100A
Detect smooth DC residual currents
Tripping sensitivity: 30mA
Connection from top or bottom
Complies with IEC61008-1, IEC62423

Features
Electromagnetic Type
Earth Leakage Protection
Breaking capacity 6KA,10KA
Rated current up to 100A
Detect smooth DC residual currents
Tripping sensitivity: 30mA
Connection from top or bottom
Complies with IEC61008-1, IEC62423

B Type
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz,pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

Application
JC3RS-B Type B RCCBs are suitable for non-linear circuits that are able to generate leakage with high direct current(higher than 6mA)and/or high frequency components, for example single-phase rectifiers, rectifiers with active correction of the power factor, continuous voltage generator with no separation from AC networks and inverted at variable frequency.

Standard IEC61008-1, EN61008-1
Electronic features Rated current In (A) 25, 40, 50, 63, 80, 100
  Type Electromagnetic
  Type(wave form of the leakage sensed) AC, A, AC-G, A-G AC-S and A-S are available
  Poles 1P+N, 3P+N
  Rated voltage Ue (V) 1P+N: 230/240  3P+N: 400/415
  Rated sensitivity IΔn 30mA, 100mA, 300mA are available
  Insulation voltage Ui (V) 500
  Rated residual making and breaking capacity IΔm 500(In=25/40A), 630(In=63A), 1000(In=80/100A)
  Rated frequency 50/60Hz
  Rated breaking capacity 6KA, 10KA
  Rated impulse withstand voltage (1.2/50) Uimp (V) 6,000
  Dielectric test voltage at ind.Freq. for 1 min (KV) 2.5
  Pollution degree 2
Mechanical features Electrical life 2,000
  Mechanical life 4,000
  Contact position indicator Yes
  Protection degree IP20
  Reference temperature for setting of thermal element() 30
  Ambient temperature(with daily average 35) -5+40
  Storage temperature() -25+70
Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
  Terminal size top/bottom for cable 25mm2/18-3AWG
  Terminal size top/bottom for Busbar 10mm2/18-8AWG
  Tightening torque 2.5N*m/22In-lbs
  Mounting On DIN rail EN 60715(35mm)
  Connection From top or bottom are available