JCB3-63DC Circuit Miniature Breaker 1000V DC

Minaturae ambitus ruptores ad usum cum DC voltages.Idea ad systemata communicationis pv DC systemata.

Proprium consilium salutis tuae!
Brevis circuitus et cultro praesidio
Fractio facultatem ad 6ka
Cum contactu indicator
Vena rated usque ad 63A
Rated intentione usque ad 1000V DC
1 Pole , 2 poli , 3 poli , 4 pertica praesto sunt
Parere IEC 60898-1

Introductio:

JCB3-63DC minima DC ruptor circuli solaris / photovoltaici PV systematis solaris, industriae repositionis aliorumque applicationum DC directum ordinatur. Hi maxime inter batteries et invertarios hybridos collocantur.
JCB3-63DC DC ruptor ambitus praebet arcum scientificum exstinguendum et mico obice technologiam ad intermissionem celeris et tutam hodiernam implendam.
JCB3-63DC DC ruptor circuitionis tutela est fabrica tam scelesto quam electromagnetica emissione instructa quae praesto est in 1 polo, 2pole, 3 polo et 4 pertica versionibus.Facultas mutandi 6kA est secundum IEC/EN 60947-2.DC aestimatio intentionis 250V per polum est, aestimata intentione usque ad 1000V DC.
JCB3-63DC circuii ruptor praesto est cum currentibus aestimatis 2A ad 63A.
JCB3-63DC dc ambitus ruptor novas lineas, meliores nexus, superiores effectus et gradus securitatis augebat.Capacitas fracta ad 6kA est.
JCB3-63DC dc ambitus ruptor obstrui potest (per padlocking fabrica) in OFF positione ut mensura tutior ad remotionem invertentis PV
Cum culpa currenti in adversa directione ad currentem operantem influere possit, praevaricator ambitus JCB3-63DC contra quemlibet currentem bidirectionalem deprehendere et protegere potest.Ut institutionis salus servetur, oportet, secundum varias applicationes rationes, ambitum ruptorem miscere;
• residua monetae in AC fine fabrica;
• culpa locum detector (magna fabrica Nulla) ad DC finem
• tutela terrae circa finem DC ruptor
In omnibus casibus, actio celeritatis de situ ad culpam purgandam requiretur (praesidium non servatur in eventu duplicis culpae).JIUCE JCB3-63DC dc Circuitu doli non sunt polaritas sensitiva: (+) et (-) fila sine ullo periculo inverti possunt.Circuitus ruptor est: traditus cum tribus claustrum inter-polium ad distantiam distantiam inter duos connectores adjacentes auctam praebendam

Depictio producti:

JCB3-63DC

Maxime features

● JCB3-63DC circuit ruptor applicationes DC

Non verticitatem, Securus wiring

Rated intentione usque ad 1000V DC

● Ratum mutandi facultatem 6 KA secundum IEC/EN 60947-2

Insulation voltage Ui 1000V

Ratus impetus sustinere intentione Uimp (V) 4000V

Current limitandi classis III

Back-up fuse with high selectivity, thanks to low let-through energy .

Contact situ indicator rubra - viridis

Rated excursus usque ad LXIII A

● Available in1 Pole, 2 poli, 3 poli et 4 poli

1 poli=250Vdc, 2 poli=500Vdc, 3 poli=750Vdc, 4 poli=1000Vdc.

Compatible cum ACUS seu Orem genus vexillum busbars

● destinatum ad Solarem, PV, industriam repositionis et DC applicationes alias

JCB3-63DC-1

Technical data

Standard: IEC60947-2, EN60947-2

● Ratum current: 2A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;

Ratum est opus intentione: 1P:DC250V, 2P:DC500V, 3P:DC 750V, 4P:DC1000V

Rated fractionis facultatem: 6ka

pollutio gradus, 2

Rated impulsus resistendi intentione (1.2/50) : 4kV

thermo- magnetica emissio propria: B curva, C curva

● Mechanica vita: 20000 times

Electrical vita: 1500 times

Praesidium gradum: IP20

Ambiens temperatus (≤35℃ cotidie mediocris):-5℃~+40℃

Contact situ indicator: Viridis=OFF, Red=ON

Terminatio nexu generis: cable / pin genus busbar

Adscendens: On DIN rail EN 60715 (35mm) per ieiunium fabrica

commendatur torque: 2.5Nm

Standard IEC/EN 60898-1 IEC/EN 60947-2

Electrical features

In current rated (A) 1, 2, 3, 4, 6, 10, 16;
20, 25, 32, 40, 50, 63, 80;
Poloni 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P .
Rated voltage Ue (V) 230/400~240/415
Nulla voltage Ui (V) 500
Rated frequency 50/60Hz
Rated facultatem fractionis 10 KA
Energy cautum genus 3  
Ratum impetus sustinere intentionis (1.2/50) Uimp (V) 4000
Dielectric test voltage in ind.Freq.for 1 min (kV) 2
Pollutio gradus 2
Potestas damnum per polum Ratum est vena (A)
1, 2, 3, 4, 5, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63, 80;
Thermo-magnetica release natura B, C, D 8-12In, 9.6-14.4In

Mechanica features

Vita electrica 4, 000
Mechanica vita 20, 000
Contact situ indicator Ita
Praesidium gradum IP20
Reference temperatus ad occasum elementum scelerisque (℃) 30
Ambiens temperatus (≤35 cotidie mediocris) -5...+40
Temperatio repono (℃) -35...+70
Institutionem Terminatio nexu generis Cable/U-type busbar/pin-type busbar
Terminatio magnitudinis top / imo ad funem 25mm2 / 18-4 AWG
Terminatio magnitudinis top / imo ad Busbar 10mm2 / 18-8 AWG
tensus tensus 2.5 N*m/22 In-Ibs.
Adscendens On DIN rail EN 60715 (35mm) ope clip fabrica
Connection A summis

Compositum
cum
Accessories

Contactus auxiliaris Ita
Shunt emissio Ita
Sub voltage emissio Ita
Terror contactus Ita
JCB3-63DC C curvis

Dimensiones

Dimensiones

Wiring tabula

wiring tabula

Reliable funem praesidium

MCB tuentur retinacula contra damnum propter onera et circuitus breves: In eventu periculosorum currentium, circa solutionem bimetallicorum ruptor scelerisque emissio potestatem copiam disiunget.In eventu circuli brevi, emissio electromagnetica potestatem copiam tempestive disiunget

Nuntius us